The importance of checks...

When a BIRD-OUT® Evolution system is installed, a few simple checks are needed. As soon as the first few metres are installed and the + and earth wires are connected to the electrifier unit, it is important to check that there is enough power along the line.
This should preferably be done with a joulemeter or, failing that, with a 10 kV tester. With the 10 kV tester, there is no way of quantifying the energy (the discomfort felt by the bird).
If checks show that there is no power at the start of the line, this means that the electrifier unit is not properly connected or that the earth connection is faulty. In this case, the earth should immediately be checked with one of the two instruments.
If the system is properly connected to earth, none of the tester displays should light up.
Any improvement of the earth connection will improve the efficiency of the BIRD-OUT® Evolution system and will be measurable using the joulemeter.
Subsequently, we recommend checking the quality of the installation (conductors, insulators, connections, drain) by measuring the power at several points along the line:
a) if the values shown by the joulemeter are high and remain the same or are only slightly different, then the installation is functionning perfectly;
b) if values are low from the start to the end of the installation and do not vary too much, that means there is a major drain on the line (short circuit).

Statement of compliance

We declare that the generator’s design complies with the requirements of electromagnetic compatibility laid down in: . Directive 89/336/EEC . Directive 92/21/EEC . Directive 93/68/EEC as well as the requirements of safety standards applicable to electrifier units: . NF en 61011 . NF en 55015 . NF en 60555-2

 
 
Published on Monday 7 January 2008

 
 
 
The others articles in the same section :
 
Published on Monday 7 January 2008
 
Published on Monday 7 January 2008
 
Published on Monday 7 January 2008
 
Published on Monday 7 January 2008
 
Published on Monday 7 January 2008
 

accessoires

SELCLEANING®

Ref. Description Packaging
SEL003Selcleaning® 1 liter can
 

SELFIXING® SILICONE

Ref. Description Packaging
SIL001 Selfixing® silicone 310 ml cartridge
 

5000 V CABLE

Ref. Description Packaging
EV0009 5000 V cable spool of 100 m
 

10 KV TESTER

Ref. Description Packaging
EV0010 10 kV tester per unit
 

CENTRAL GENERATOR 01

Ref. Description Packaging
EV0050 Central generator 01 per unit
 

POCKET JOULEMETER

Ref. Description Packaging
EV0020 Pocket Joule-meter per unit
 
 
 
 